Electronic Oval Gear Meter Diesel Fuel Gasoline Kerosene Oil Flow Meter

FOB Reference Price:Get Latest Price
US $158-500 / Units | 1 Unit/Units (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Liaoning, China (Mainland)
Brand Name:
METERY
Model Number:
MT-OGM
Sort:
Oval Gear Meter Diesel Fuel Gasoline Kerosene Oil Flow Meter
Origin:
Dalian China
web:
www.meterytech.com
Supply Ability
Supply Ability:
200 Set/Sets per Month
Packaging & Delivery
Packaging Details
Carton of Electronic Oval Gear Meter Diesel Fuel Gasoline Kerosene Oil Flow Meter
Port
Dalian or optional
Lead Time :
Shipped in 7 days after payment

 

OGM Digital Fuel Diesel Flow Meter Electronic Oval Gear Meter Diesel Fuel Gasoline Kerosene Oil Flow Meter

 

Introduction of  OGM Digital Fuel Diesel Flow Meter

     The product control panel is designed with modular design, with complete functions, simple structure, convenient operation and so on. Can be widely used in petroleum, chemical, pharmaceutical, transportation, food industry and commerce. The screen is a digital liquid crystal display, the screen is divided into three lines: the top line is regarded as the current measurement data, the next line of the cumulative data.

 

 

Technical parameters

Model

OGM-25

OGM-40

OGM-50

Metric Diameter

1"

1.5"

2" 

Min Flow L/min

12

25

30

Max Flow L/min

120

250

300 

Accuracy

±0.5%

±0.5%

±0.5%

Repeatibility

±0.3%

±0.3%

±0.3%

Max viscosity

1000CPS

1000CPS

1000CPS

Max working pressure

3.4MPa

1.8MPa

1.8MPa

Single Count

0.00-9999.9

0.00-9999.9

0.00-9999.9

Total Count

0.00-999999.9

0.00-999999.9

0.00-999999.9

 

 

Key Opertion Instruction

1.. On the left CLEAN key, starting and cleared, in the middle of the START key, set up, the right for the TOTAL key, the total amount of display and class total display

2, start: press ON/CLEAN key to boot, or the sensor has a measurement pulse, can be switched on. The machine automatically shut down 4-5 minutes without any operation..

3 view total: in the normal display state press TOTAL key, the screen display TOTAL, the following row of figures is the total cumulative. 10 seconds after the automatic return to normal display.

4 when the data is clear, in the normal state of the display, press ON/CLEAN to clear when the data.

5 clear class total: in the normal display state press TOTAL button, when the screen display TOTAL, the following row shows the figure is the total cumulative, press TOTAL key again, showing a total flash, then press ON/CLEAN button to clear the value, return to normal after 3 seconds.

6. Adjustment coefficient in the normal state, not counting pulse, waiting for 5 seconds, press the start button to keep 5 seconds, entering coefficient adjustment mode, this row display has some coefficient, a flashing. Press ON/CLEAN button to 'Add', press TOTAL key to 'minus', according to the START shift, after modification, long press START wait for 1 seconds, save the revised value, and return to normal display. If you do not operate, after 30 seconds will automatically return to normal display. The modification is based on the actual measured value and display value, the actual value divided by the display value, and then multiplied by the existing coefficient is to modify the value of the. Simple generalization: when the system is large, the relative oil will be reduced. System to minor. Oil will increase.

 

 

Working Principle

The measuring of the Digital oval gear flowmeter is mainly composed of two mutual meshing gears, the shell and the electronic parts, as shown in Figure:

 

1. flow meter installed in the oil pump outlet, if installed in the inlet, the filter pressure is damaged, so that the negative pressure of the pump increases, so that the flow meter is not accurate, the pump inlet and outlet also need to be completely sealed, otherwise it will make the flow meter is not accurate.

2. in front of the flow meter should be installed in the filter, do not make more than 0.2MM particles through, to prevent the flow of particles from the particle surface stuck or blocked. Filters should be cleaned regularly.

3. In front of flowmeter should be equipped with one-way valve and the pipeline liquid flows in only one, to prevent reverse gear meter, or idling inaccurate measurement of flowmeter.

4. meter should be installed correctly, the meter display screen should be 90 degrees upward or sideways installation, not installed.

5. flow meter installation direction should be the same as the direction of the arrow on the shell body, the same direction of the liquid, the installation position should pay attention to facilitate reading.

6. flow meter pressure loss is proportional to the liquid flow, the liquid viscosity increases, and the pressure loss increases.

 

 

 

Calibration error coefficient

 

     In standby mode or current charging status, press START key for 5 seconds to enter the state of the error coefficient. In the middle of a row in front of the E- and the last bit of the digital flash display, press START button, digital shift, (flashing digital displacement), press CLEAR button to "add", press TOTAL button for "minus" to modify the current flicker bit value.. This coefficient increases when the amount of oil is reduced, the smaller the coefficient is, the more oil the oil is. 5 seconds to end the error coefficient calibration. Return to display the current charging status. After calibration of the error coefficient, the new measurement pulse input is used to calibrate the error coefficients. Error coefficient calibration range: 0 - 20000. The error of the flow meter and the oil is about 0.05%.

 

 

Common failure and troubleshooting

 

The 

phenomenon

Cause

Exclusion method

Gear rotary 

hard

1.When the installation of impurities 

into the flow, the flow meter inside gear

After the cleaning,it is removed, 

please put it based

on the gear marked 

2.The liquid is not clear, the filter is 

filled with impurities

Cleaning filter, remove impurities

3.Too small pressure to be tested

Increase the pressure

 

 

 

4.The wheel stuck

 

5.Flow over a specified rating value

 

6.The direction of the flow of the liquid

 is opposite to the direction of the shell.

 

 

 

 

 

Measurement

 error increases

7.Flow is too small, below the specified 

value

Enlarge the flow

8.Bypass leakage

Check the bypass to 

prevent leakage

9.Over a long period of time, gear wear 

too much

Change gear

10.Liquid containing gas, liquid viscosity 

and the viscosity difference between the 

test liquid viscosity

Adjustment coefficient

11.Inlet and pump suction port 

connection is not sealed

 

 

 

Workshop Views

 

 

 

International Certificate

 

 

 

 

Reliable Team

 

Transaction History
http://metery.en.alibaba.com/company_profile/transaction_history.html

Related links of Our other Instruments

Electromagnetic flowmeter

Coriolis mass flowmeter

Oval gear flowmeter

Ultrasonic flowmeter

Turbine flow meter

Vortex flowmeter

Rotameter

Solid flowmeter

Radar level transmitter

Ultrasonic level transmitter

Magnetostrictive level transmitter

Pressure transmitter

Temperature Transmitter

 

 

Email:  info(at)metery-tech.com   sales(at)meterytech.com

----------------------------------------------------------------------------------------------------------
Cellphone: +86 18841127006
Skpye: meterytech
Whatsapp: +86 18841127006
Wechat: Kai123263788
QQ: 123263788

Metery Technology Co., Ltd

----------------------------------------------------------------------------------------

                                               www.meterytech.com

   Our company is specialized in the manufacture and supply of flow meter and flow measurement devices. We can supply a wide range of flow meters from simple low cost of variable area flow meters to high accuracy Turbine andelectromagnetic flow meter types.
We manufacture and Stockhold liquid flow meters, solid flow meter and gas flow meter types including waterelectromagnetic flow meters in many sizes.
We can offer flow meters for many applications such as fuel flow meter, oil flow meter, diesel flow meter phosphate ester, water, water-based fluids, air other compressed gas and petrol flow meter type.
With our chemically resistant, high accuracy digital flow meter designs with pulse outputs, we can handle almost any fluid. For hazardous areas turbine meters can be supplied with ATEX Intrinsically safe pick off coils.
We have a large range of secondary display instrumentation to choose from with flow rate, total flow throughput, retransmission, batching and scaled pulse option, etc.
Electromagnetic flow meters are available in full bore and insertion type designs. The displays on these can show both flow rate and flow total.
We are experts in the selection and supply of flow measurement equipment and any type of flow meter can be specified and supplied. We also stock hold hundreds of low cost all plastic variable area types for quick delivery. They are available with low/high flow switches and transmitters.
We are well placed to provide many types of instruments on very short lead times. With shipments of most meters in 2-5 days our "promise to ship" rate is at 99.5%.